• Outer dimension (mm): 300 x 440 x 390
• Inner furnace dimension (mm): 120 x 225 x 110
•…
• Outer dimension (mm): 400 x 470 x 450
• Inner furnace dimension (mm): 160 x 245 x 130
•…
• Outer dimension (mm): 570 x 575 x 510
• Inner furnace dimension (mm): 230 x 305 x 200
•…
• Model number: GLD-051
• Exhaust speed (50/60Hz) (L/min): 50/60
• Achieving pressure (Pa): Gas ballast close 6.7 x 10^-2,…
• Model number: GLD-137CC
• Exhaust speed (50/60Hz) (L/min): 135/162
• Ultimate pressure (Pa): Gas ballast close 6.7 x 10^-1Pa…
• Model number: GLD-202BB
• Exhaust speed (50/60Hz) (L/min): 200/240
• Ultimate pressure (Pa): Gas ballast close 6.7 x 10^-1Pa…
• Model number: GCD-051X
• Size (mm): 165.5 x 419 x 222.7
• Exhaust speed (effective) (L/min): 50/60 (50/60Hz)
•…
• Model number: GCD-136X
• Exhaust speed (effective) (L/min): 135/162 (50/60Hz)
• Size (mm): 170 x 493 x 241.1
•…
• Model number: GCD-201X
• Exhaust speed (effective) (L/min): 200/240 (50/60Hz)
• Size (mm): 170 x 509.5 x 241.1
•…
• Model number: Gas replacement unit
• Flowmeter: 10L/min
• Regulator Set pressure range: 0.1 - 0.8MPa
• Bracket fitting x 2 pieces…
• Size: f100 x 304mm/piece
• Model number: Replacement activated carbon filter for neutral gas
• Quantity: 1 set (16 pcs) …
• Size: f100 x 304mm/piece
• Type of activated charcoal: for acid gas
• Adaptive model: DL-06
• Quantity: 1 set (6 pcs)…
• Size: f100 x 304mm/piece
• Type of activated charcoal: for basic gas
• Adaptive model: DL-06
• Quantity: 1 set (6 pcs)…
• Size: f100 x 304mm/piece
• Type of activated charcoal: for neutral gas
• Adaptive model: DL-06
• Quantity: 1 set (6 pcs)…
• Size: f100 x 304mm/piece
• Model number: Replacement activated carbon filter for acid gas (10 pieces)
• Dry …
• Size: f100 x 304mm/piece
• Model number: Replacement activated carbon filter for basic gas (10 pieces)
• Dry …
• Size: f100 x 304mm/piece
• Model number: Replacement activated carbon filter for neutral gas (10 pieces)
• Dry …
• Model number: Air tight 800+PCRM-01
• Size (mm): 1090 x 535 x 500
• Minimum operation differential pressure/Minimum display units pressure:…
• Size (mm): 485 x 890 x 450
• Minimum differential pressure/Minimum display unit pressure: 0.01 kPa/0.05 kPa
• Material : Main…
• Size (mm): 535 x 1090 x 500
• Minimum differential pressure/Minimum display unit pressure: 0.01 kPa/0.05 kPa
• Material : Main…
• Size (mm): 535 x 1290 x 500
• Minimum differential pressure/Minimum display unit pressure: 0.01 kPa/0.05 kPa
• Material : Main…
• Size (mm): 65 x 175 x 255
• Connection port: outer diameter f6mm rigid tube or Rc 1/8 female screw
•…
• Size (mm): 65 x 185 x 255
• usable gas: CO2
• Connection port: outer diameter f6mm rigid tube or Rc…
• Model number: AVRD tube joint f12
• This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Model number: AVRD tube joint f15
• This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Model number: AVRD tube joint f18
• This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Model number: AVRD tube joint f8
• This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Sliding: 15/25
• Material: Borosilicate glass -1
• Outside diameter: f8mm
• Sliding Bottom Length: 150 mm …
• Sliding: 19/38
• Material: Borosilicate glass -1
• Outside diameter: f8mm
• Sliding Bottom Length: 150 mm …
• Sliding: 24/40
• Material: Borosilicate glass -1
• Outside diameter: f8mm
• Sliding Bottom Length: 150 mm …
• Gas name: Ammonia
• measurement range (ppm) : 0.05 to 3.52%
• Quantity : 1 box (Iru 10 pieces)
…
• Model number: DGB-1000
• Size (mm): 1225 x 758 x 62
• Usage: Gas replacement 3
• Material: Body/stainless steel (SUS304), Window/PMMA…
• Outer dimensions (mm): 210 x 210 x 290
• Inner dimensions (mm): 50 x 140
• Inner capacity (L): 0.3
• Temperature…
• Detecting tube name: 92 Acetaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration…
• Detecting tube name: 92M acetaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration…
• Detecting tube name: 92L acetaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration…
• Detecting tube name: 81 Acetic acid
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 81L acetic acid
• Number of measurements of 1 box: 10
• Expiration date (year): 2…
• Detecting tube name: 151L Acetone
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration…
• Detecting tube name: 180. Amines
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 180L amines
• Number of measurements of 1 box: 10
• Expiration date (year): 2
•…
• Detecting tube name: 3M Ammonia
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 3La Ammonia
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 3L Ammonia
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 121L benzene
• Number of measurements of 1 box: 5
• Expiration date (year): 3
•…
• Detecting tube name: 121S benzene
• Number of measurements of 1 box: 5
• Expiration date (year): 3
•…
• Detecting tube name: 126UH Carbon dioxide
• Number of measurements of 1 box: 10
• Measurement gas…
• Detecting tube name: 126SH Carbon dioxide
• Number of measurements of 1 box: 10
• Measurement gas…
• Detecting tube name: 2HH carbon dioxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 2H carbon dioxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 2L carbon dioxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 2LL carbon dioxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 2LC carbon dioxide
• Number of measurements of 1 box: 10
• Expiration date (year): 2
…
• Detecting tube name: 13 carbon disulfide
• Number of measurements of 1 box: 5
• Expiration date (year): 3
…
• Detecting tube name: 1L Carbon monoxide
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 1LL Carbon monoxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 1LC carbon monoxide
• Number of measurements of 1 box: 10
• Expiration date (year): 2
…
• Detecting tube name: 8LL chlorine
• Number of measurements of 1 box: 10
• Expiration date (year): 1 (refrigeration…
• Detecting tube name: 8La chlorine
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 138 Dichloromethane
• Number of measurements of 1 box: 5
• Expiration date (year): 3
•…
• Detecting tube name: 112 Ethanol
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 112L Ethanol
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 163L Ethylene oxide
• Number of measurements of 1 box: 5
• Expiration date (year): 1…
• Detecting tube name: 163LL ethylene oxide
• Number of measurements of 1 box: 5
• Expiration date (year): 1…
• Detecting tube name: 91 formaldehyde
• Number of measurements of 1 box: 5
• Expiration date (year): 3
•…
• Detecting tube name: 91L formaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 3 (Refrigeration…
• Detecting tube name: 91LL formaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 1 (refrigeration…
• Model number: 232
• Measurement gas name: 1,2-Dichloroethane
• Measurement range (ppm): 1 - 39
• Quantity: 1 box…
• Model number: 233
• Measurement gas name: Chloropicrin
• Measurement range (ppm): 0.045 - 22
• Quantity: 1 box…
• Detecting tube name: 14M Hydrogen chloride
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 14L Hydrogen chloride
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 12LL hydrogen cyanide
• Number of measurements of 1 box: 10
• Expiration date (year): 2
…
• Detecting tube name: 17LL hydrogen fluoride
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 17 hydrogen fluoride
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 32 hydrogen peroxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 4LL hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 4L hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 4LT hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 4LK hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 4H Hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 4HM hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 4M hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 103 Lower hydrocarbon
• Number of measurements of 1 box: 9
• Expiration date (year): 2
…
• Detecting tube name: 70 mercaptan
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 70L mercaptan
• Number of measurements of 1 box: 10
• Expiration date (year): 2
•…
• Detecting tube name: 111L methanol
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 71 Methyl mercaptan
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 11L Nitrogen oxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 10 Nitrogen oxide
• Number of measurements of 1 box: 5
• Expiration date (year): 3
…
• Detecting tube name: 31B Oxygen
• Number of measurements of 1 box: 5
• Expiration date (year): 3
•…
• Detecting tube name: 18L Ozone
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 6 Water vapor
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 6LLP water vapor
• Number of measurements of 1 box: 10
• Expiration date (year):…
• Detecting tube name: 5Lb sulfur dioxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 5L sulfur dioxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
…
• Detecting tube name: 122 Toluene
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 122L toluene
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•…
• Detecting tube name: 132M, trichloroethylene
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration…
• Detecting tube name: 132L Trichloroethylene
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration…
• Detecting tube name: 132LL trichloroethylene
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration…
• Size (mm): 600 x 1107 x 580
• Material: Main unit/Reinforced Transparent PMMA (acrylic), Valve Vacuum Mounting Unit/Polycarbonate
• Pass box…
• Model number: GTB-60
• Material: Cover/PC (polycarbonate), Wire fastener/PA (nylon 66)
• Recommended gas flow: To 3L/min (MAX)
• Valve: IN/PISCO BVLC20-0602,…
• Model number: GTB-105
• Material: Cover/PC (polycarbonate), Wire fastener/PA (nylon 66)
• Recommended gas flow: To 3L/min (MAX)
• Valve: IN/PISCO BVLC20-0602,…
• Model number: DG-1N
• Outer dimension (mm): 450 x 450 x 900
• Inner dimension (mm): 406 x 400 x 740
•…
• Model number: DG-2N
• Outer dimension (mm): 900 x 450 x 900
• Inner dimension (mm): 856 x 400 x 740
•…
• Model number: DG-3N
• Outer dimension (mm): 600 x 650 x 1800
• Inner dimension (mm): 536 x 600 x 675…
• Model number: DG-4N
• Outer dimension (mm): 1200 x 650 x 1800
• Inner dimension (mm): 1136 x 600 x 675…
• Model number: Gas replacement unit for TMF-300N
• Adaptive furnace core tube: Ceramic, Alumina 99%, Quartz
• Accessories: Aluminum cover x…
• Model number: Unit for quartz furnace core tube for TMF-500N
• Adaptive furnace core tube: Quartz …
• Model number: Gas replacement unit for TMF-500N
• Adaptive furnace core tube: Ceramic, Alumina 99%
• Accessories: Aluminum cover x 2,…
• Model number: CGB
• Size (mm): 400 x 400 x 400 *Excluding knob.
• Usage: Gas replacement
• Body material: PMMA (acrylic)
•…
• Model number: Metal fitting for fixing decompression valve (1 piece)
• Provided with palm-sized small container to fill high-pressure…
• Model Number: AS-800 S
• Size (mm): 800 x 600 x 620
• Usage: Gas replacement
• Material: Main frame / stainless…
• Model number: ATM-02
• Size (mm): 190 x 170 x 122
• Hot plate: Aluminum block (teflon coating)
• Heater: Cartridge heater…
• Weight: 440g
• Diameter x height (mm): f78 x 103
• Operation unit length: 40mm
• Model number: dragon220
• This gas…
• Model number: MAS-1
• Vacuum attainment level: -75kPa
• Highest exhaust Pressure forces: 0.2MPa
• Intake gas flow rate 12L/min
• Exhaust gas…
• Model number: OSL-S
• Size (mm): 900 x 450 x 1800
• Specification: with 5 shelf boards
• Material: Body/Stainless steel (SUS304)
•…
• Model number: OSL-H
• Size (mm): 900 x 450 x 1800
• Specification: without shelf board
• Material: Body/Stainless steel (SUS304)
• Ozone…
• Material: External/steel plate melamine bake coating, Internal/stainless steel (SUS430),
• Shelf board mounting pitch: 25mm
• Shelf board load capacity: Approximately…
• Outer dimension (mm): f50 x 700
• Inner furnace dimension (mm): f44 x 700
• Model number: Quartz furnace core tube…
• Model number: Quartz furnace core tube
• Outer diameter: f30 x f24 x 500mm
• If reactor core pipe and…
• Model number: Quartz furnace core tube
• Outer diameter: f50 x f44 x 500mm
• If reactor core pipe and…
• Model number: Quartz furnace core tube
• Outer diameter: f70.5 x f64.5 x 500mm
• If reactor core pipe and…
•
• Target gas: 1 Type of Ar, N2O, CO2, He Air C2H2
• Primary pressure: 10 kg…
• Model number: Activated carbon filter (for acid gas)
• Size (mm): 150 x 150 x 20
• Weight (kg): 0.12
•…
• Model number: N2ADP
• Tube adapter (AJX-N2BR only)
• Oxygen concentration conversion
• Displays indicated value is 100-oxygen density(%) and degree…
• Pressure setting range (kPa): 101.3 to 0.0 (atmospheric pressure)
• Minimum display unit: 0.1kPa
• Control method: solenoid valve or power…