JavaScript seems to be disabled in your browser.
You must have JavaScript enabled in your browser to utilize the functionality of this website. Click here for instructions on enabling javascript in your browser.
0 items
• Outer dimension (mm): 300 x 440 x 390 • Inner furnace dimension (mm): 120 x 225 x 110 •…
• Outer dimension (mm): 400 x 470 x 450 • Inner furnace dimension (mm): 160 x 245 x 130 •…
• Outer dimension (mm): 570 x 575 x 510 • Inner furnace dimension (mm): 230 x 305 x 200 •…
• Model number: GLD-051 • Exhaust speed (50/60Hz) (L/min): 50/60 • Achieving pressure (Pa): Gas ballast close 6.7 x 10^-2,…
• Model number: GLD-137CC • Exhaust speed (50/60Hz) (L/min): 135/162 • Ultimate pressure (Pa): Gas ballast close 6.7 x 10^-1Pa…
• Model number: GLD-202BB • Exhaust speed (50/60Hz) (L/min): 200/240 • Ultimate pressure (Pa): Gas ballast close 6.7 x 10^-1Pa…
• Model number: GCD-051X • Size (mm): 165.5 x 419 x 222.7 • Exhaust speed (effective) (L/min): 50/60 (50/60Hz) •…
• Model number: GCD-136X • Exhaust speed (effective) (L/min): 135/162 (50/60Hz) • Size (mm): 170 x 493 x 241.1 •…
• Model number: GCD-201X • Exhaust speed (effective) (L/min): 200/240 (50/60Hz) • Size (mm): 170 x 509.5 x 241.1 •…
• Model number: Gas replacement unit • Flowmeter: 10L/min • Regulator Set pressure range: 0.1 - 0.8MPa • Bracket fitting x 2 pieces…
• Size: f100 x 304mm/piece • Model number: Replacement activated carbon filter for neutral gas • Quantity: 1 set (16 pcs) …
• Size: f100 x 304mm/piece • Type of activated charcoal: for acid gas • Adaptive model: DL-06 • Quantity: 1 set (6 pcs)…
• Size: f100 x 304mm/piece • Type of activated charcoal: for basic gas • Adaptive model: DL-06 • Quantity: 1 set (6 pcs)…
• Size: f100 x 304mm/piece • Type of activated charcoal: for neutral gas • Adaptive model: DL-06 • Quantity: 1 set (6 pcs)…
• Size: f100 x 304mm/piece • Model number: Replacement activated carbon filter for acid gas (10 pieces) • Dry …
• Size: f100 x 304mm/piece • Model number: Replacement activated carbon filter for basic gas (10 pieces) • Dry …
• Size: f100 x 304mm/piece • Model number: Replacement activated carbon filter for neutral gas (10 pieces) • Dry …
• Model number: Air tight 800+PCRM-01 • Size (mm): 1090 x 535 x 500 • Minimum operation differential pressure/Minimum display units pressure:…
• Size (mm): 485 x 890 x 450 • Minimum differential pressure/Minimum display unit pressure: 0.01 kPa/0.05 kPa • Material : Main…
• Size (mm): 535 x 1090 x 500 • Minimum differential pressure/Minimum display unit pressure: 0.01 kPa/0.05 kPa • Material : Main…
• Size (mm): 535 x 1290 x 500 • Minimum differential pressure/Minimum display unit pressure: 0.01 kPa/0.05 kPa • Material : Main…
• Size (mm): 65 x 175 x 255 • Connection port: outer diameter f6mm rigid tube or Rc 1/8 female screw •…
• Size (mm): 65 x 185 x 255 • usable gas: CO2 • Connection port: outer diameter f6mm rigid tube or Rc…
• Model number: AVRD tube joint f12 • This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Model number: AVRD tube joint f15 • This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Model number: AVRD tube joint f18 • This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Model number: AVRD tube joint f8 • This is 2-stage oil-sealed high vacuum rotary pump designed with special focus…
• Sliding: 15/25 • Material: Borosilicate glass -1 • Outside diameter: f8mm • Sliding Bottom Length: 150 mm …
• Sliding: 19/38 • Material: Borosilicate glass -1 • Outside diameter: f8mm • Sliding Bottom Length: 150 mm …
• Sliding: 24/40 • Material: Borosilicate glass -1 • Outside diameter: f8mm • Sliding Bottom Length: 150 mm …
• Gas name: Ammonia • measurement range (ppm) : 0.05 to 3.52% • Quantity : 1 box (Iru 10 pieces)…
• Model number: DGB-1000 • Size (mm): 1225 x 758 x 62 • Usage: Gas replacement 3 • Material: Body/stainless steel (SUS304), Window/PMMA…
• Outer dimensions (mm): 210 x 210 x 290 • Inner dimensions (mm): 50 x 140 • Inner capacity (L): 0.3 • Temperature…
• Detecting tube name: 92 Acetaldehyde • Number of measurements of 1 box: 10 • Expiration date (year): 2 (refrigeration…
• Detecting tube name: 92M acetaldehyde • Number of measurements of 1 box: 10 • Expiration date (year): 2 (refrigeration…
• Detecting tube name: 92L acetaldehyde • Number of measurements of 1 box: 10 • Expiration date (year): 2 (refrigeration…
• Detecting tube name: 81 Acetic acid • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 81L acetic acid • Number of measurements of 1 box: 10 • Expiration date (year): 2…
• Detecting tube name: 151L Acetone • Number of measurements of 1 box: 10 • Expiration date (year): 2 (refrigeration…
• Detecting tube name: 180. Amines • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 180L amines • Number of measurements of 1 box: 10 • Expiration date (year): 2 •…
• Detecting tube name: 3M Ammonia • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 3La Ammonia • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 3L Ammonia • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 121L benzene • Number of measurements of 1 box: 5 • Expiration date (year): 3 •…
• Detecting tube name: 121S benzene • Number of measurements of 1 box: 5 • Expiration date (year): 3 •…
• Detecting tube name: 126UH Carbon dioxide • Number of measurements of 1 box: 10 • Measurement gas…
• Detecting tube name: 126SH Carbon dioxide • Number of measurements of 1 box: 10 • Measurement gas…
• Detecting tube name: 2HH carbon dioxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 2H carbon dioxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 2L carbon dioxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 2LL carbon dioxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 2LC carbon dioxide • Number of measurements of 1 box: 10 • Expiration date (year): 2…
• Detecting tube name: 13 carbon disulfide • Number of measurements of 1 box: 5 • Expiration date (year): 3…
• Detecting tube name: 1L Carbon monoxide • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 1LL Carbon monoxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 1LC carbon monoxide • Number of measurements of 1 box: 10 • Expiration date (year): 2…
• Detecting tube name: 8LL chlorine • Number of measurements of 1 box: 10 • Expiration date (year): 1 (refrigeration…
• Detecting tube name: 8La chlorine • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 138 Dichloromethane • Number of measurements of 1 box: 5 • Expiration date (year): 3 •…
• Detecting tube name: 112 Ethanol • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 112L Ethanol • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 163L Ethylene oxide • Number of measurements of 1 box: 5 • Expiration date (year): 1…
• Detecting tube name: 163LL ethylene oxide • Number of measurements of 1 box: 5 • Expiration date (year): 1…
• Detecting tube name: 91 formaldehyde • Number of measurements of 1 box: 5 • Expiration date (year): 3 •…
• Detecting tube name: 91L formaldehyde • Number of measurements of 1 box: 10 • Expiration date (year): 3 (Refrigeration…
• Detecting tube name: 91LL formaldehyde • Number of measurements of 1 box: 10 • Expiration date (year): 1 (refrigeration…
• Model number: 232 • Measurement gas name: 1,2-Dichloroethane • Measurement range (ppm): 1 - 39 • Quantity: 1 box…
• Model number: 233 • Measurement gas name: Chloropicrin • Measurement range (ppm): 0.045 - 22 • Quantity: 1 box…
• Detecting tube name: 14M Hydrogen chloride • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 14L Hydrogen chloride • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 12LL hydrogen cyanide • Number of measurements of 1 box: 10 • Expiration date (year): 2…
• Detecting tube name: 17LL hydrogen fluoride • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 17 hydrogen fluoride • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 32 hydrogen peroxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 4LL hydrogen sulfide • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 4L hydrogen sulfide • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 4LT hydrogen sulfide • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 4LK hydrogen sulfide • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 4H Hydrogen sulfide • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 4HM hydrogen sulfide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 4M hydrogen sulfide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 103 Lower hydrocarbon • Number of measurements of 1 box: 9 • Expiration date (year): 2…
• Detecting tube name: 70 mercaptan • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 70L mercaptan • Number of measurements of 1 box: 10 • Expiration date (year): 2 •…
• Detecting tube name: 111L methanol • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 71 Methyl mercaptan • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 11L Nitrogen oxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 10 Nitrogen oxide • Number of measurements of 1 box: 5 • Expiration date (year): 3…
• Detecting tube name: 31B Oxygen • Number of measurements of 1 box: 5 • Expiration date (year): 3 •…
• Detecting tube name: 18L Ozone • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 6 Water vapor • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 6LLP water vapor • Number of measurements of 1 box: 10 • Expiration date (year):…
• Detecting tube name: 5Lb sulfur dioxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 5L sulfur dioxide • Number of measurements of 1 box: 10 • Expiration date (year): 3…
• Detecting tube name: 122 Toluene • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 122L toluene • Number of measurements of 1 box: 10 • Expiration date (year): 3 •…
• Detecting tube name: 132M, trichloroethylene • Number of measurements of 1 box: 10 • Expiration date (year): 2 (refrigeration…
• Detecting tube name: 132L Trichloroethylene • Number of measurements of 1 box: 10 • Expiration date (year): 2 (refrigeration…
• Detecting tube name: 132LL trichloroethylene • Number of measurements of 1 box: 10 • Expiration date (year): 2 (refrigeration…
• Size (mm): 600 x 1107 x 580 • Material: Main unit/Reinforced Transparent PMMA (acrylic), Valve Vacuum Mounting Unit/Polycarbonate • Pass box…
• Model number: GTB-60 • Material: Cover/PC (polycarbonate), Wire fastener/PA (nylon 66) • Recommended gas flow: To 3L/min (MAX) • Valve: IN/PISCO BVLC20-0602,…
• Model number: GTB-105 • Material: Cover/PC (polycarbonate), Wire fastener/PA (nylon 66) • Recommended gas flow: To 3L/min (MAX) • Valve: IN/PISCO BVLC20-0602,…
• Model number: DG-1N • Outer dimension (mm): 450 x 450 x 900 • Inner dimension (mm): 406 x 400 x 740 •…
• Model number: DG-2N • Outer dimension (mm): 900 x 450 x 900 • Inner dimension (mm): 856 x 400 x 740 •…
• Model number: DG-3N • Outer dimension (mm): 600 x 650 x 1800 • Inner dimension (mm): 536 x 600 x 675…
• Model number: DG-4N • Outer dimension (mm): 1200 x 650 x 1800 • Inner dimension (mm): 1136 x 600 x 675…
• Model number: Gas replacement unit for TMF-300N • Adaptive furnace core tube: Ceramic, Alumina 99%, Quartz • Accessories: Aluminum cover x…
• Model number: Unit for quartz furnace core tube for TMF-500N • Adaptive furnace core tube: Quartz …
• Model number: Gas replacement unit for TMF-500N • Adaptive furnace core tube: Ceramic, Alumina 99% • Accessories: Aluminum cover x 2,…
• Model number: CGB • Size (mm): 400 x 400 x 400 *Excluding knob. • Usage: Gas replacement • Body material: PMMA (acrylic) •…
• Model number: Metal fitting for fixing decompression valve (1 piece) • Provided with palm-sized small container to fill high-pressure…
• Model Number: AS-800 S • Size (mm): 800 x 600 x 620 • Usage: Gas replacement • Material: Main frame / stainless…
• Model number: ATM-02 • Size (mm): 190 x 170 x 122 • Hot plate: Aluminum block (teflon coating) • Heater: Cartridge heater…
• Weight: 440g • Diameter x height (mm): f78 x 103 • Operation unit length: 40mm • Model number: dragon220 • This gas…
• Model number: MAS-1 • Vacuum attainment level: -75kPa • Highest exhaust Pressure forces: 0.2MPa • Intake gas flow rate 12L/min • Exhaust gas…
• Model number: OSL-S • Size (mm): 900 x 450 x 1800 • Specification: with 5 shelf boards • Material: Body/Stainless steel (SUS304) •…
• Model number: OSL-H • Size (mm): 900 x 450 x 1800 • Specification: without shelf board • Material: Body/Stainless steel (SUS304) • Ozone…
• Material: External/steel plate melamine bake coating, Internal/stainless steel (SUS430), • Shelf board mounting pitch: 25mm • Shelf board load capacity: Approximately…
• Outer dimension (mm): f50 x 700 • Inner furnace dimension (mm): f44 x 700 • Model number: Quartz furnace core tube…
• Model number: Quartz furnace core tube • Outer diameter: f30 x f24 x 500mm • If reactor core pipe and…
• Model number: Quartz furnace core tube • Outer diameter: f50 x f44 x 500mm • If reactor core pipe and…
• Model number: Quartz furnace core tube • Outer diameter: f70.5 x f64.5 x 500mm • If reactor core pipe and…
• • Target gas: 1 Type of Ar, N2O, CO2, He Air C2H2 • Primary pressure: 10 kg…
• Model number: Activated carbon filter (for acid gas) • Size (mm): 150 x 150 x 20 • Weight (kg): 0.12 •…
• Model number: N2ADP • Tube adapter (AJX-N2BR only) • Oxygen concentration conversion • Displays indicated value is 100-oxygen density(%) and degree…
• Pressure setting range (kPa): 101.3 to 0.0 (atmospheric pressure) • Minimum display unit: 0.1kPa • Control method: solenoid valve or power…